4. Specifications

4.1 CIM module

General data
Ambient humidity
Operating temperature
Storage temperature
GENIbus visual diagnostics
Power supply (CIU)
GENIbus connection type (CIU)
CIU box enclosure class
CIU box dimensions (H x W x D)

4.2 CIM 150 PROFIBUS DP

The table below provides an overview of the specifications for
Grundfos CIM 150 and CIU 150. For further details, please refer
to the specific sections of this functional profile.
PROFIBUS DP specifications
PROFIBUS implementation class
PROFIBUS connector
PROFIBUS connection type
Maximum cable length
Slave address
Line termination
Recommended cable cross-section
Supported transmission speed
PROFIBUS visual diagnostics
Maximum number of PROFIBUS devices
at a physical network segment

4.3 CIM 500 PROFINET IO

The table below provides an overview of the specifications for
Grundfos CIM/CIU 500 ethernet for PROFINET IO. For further
details, please refer to the specific sections of this functional
profile.
PROFINET IO specifications
Application layer
Transport layer
Internet layer
Link layer
Ethernet cable
Maximum cable length
Transmission speed
Industrial Ethernet protocols
6
Description
30-95 %
-20 to +45 °C
-25 to +70 °C
LED2
24-240 V
RS-485, 3-wire + screen
IP54
182 x 108 x 82 mm
Description
DP-V0
Screw-type terminal
RS-485, two-wire
100 metres at 12 Mbits/s
1-126
On or off
2
0.20 - 0.25 mm
9.6 Kbits/s to 12 Mbits/s
LED1
32
Description
DHCP, HTTP, Ping, FTP, SMTP, SNTP,
PROFINET IO
TCP
Internet protocol V4 (IPv4)
ARP, Media Access Control (ethernet)
CAT5, CAT5e or CAT6
100 metres at 10/100 Mbits/s
10 Mbits/s, 100 Mbits/s
PROFINET IO, Modbus TCP
Pumpland.ru
Comments
Relative, non-condensing.
Will be in one of these states:
Off, permanently green, flashing red, permanently
red.
See section
for PROFIBUS DP
5.6 Status LEDs
and section
for PROFINET IO.
6.5 Status LEDs
Located in the CIU.
Conductors: A, B and Y.
Comments
Intelligent pump profile.
A, B, DGND, VP (+5 V).
Conductors: A, B.
Corresponds to 328 feet. See section
transmission rates and cable
length.
Set via rotary switches SW3 and SW4.
See section
5.4 Setting the PROFIBUS
Set via DIP switches SW1 and SW2.
See section
5.5 Termination
resistors.
Auto detected
AWG24 or AWG23
Auto detected.
Off, permanently green, flashing red, permanently
red.
See section
5.6 Status
LEDs.
Up to 125 devices if repeaters are used (physically
segmented network).
Comments
Rotary switch in position 0.
Supports auto cable-crossover detecting (Auto-
MDIX)
Corresponds to 328 feet.
Auto-detected.
Selected with rotary switch, section
Industrial Ethernet
protocol.
5.3.1 Data
address.