4.1 Fan and Fan Filter

Inspect the fan filter periodically and clean it when needed. The temperature inside the
Drive unit may get too high and the Drive unit may not operate properly if the filter is not
kept clean.
For the inspection schedule of the fan filter, refer to Maintenance 2. Regular Maintenance
Inspection.
4.1.1 Cleaning and Replacing the Fan Filter
Fan Filter
(1) Turn OFF the Drive unit.
Remove
(2) Pull out the two plastic fasteners
(3) Remove the fan filter.
Fan Filter
(1) Mount the fan filter.
Mount
(2) Insert the two flared parts of the inlet
(3) Push the two plastic fasteners in the
(4) Plug in the power connector. Turn ON the Drive unit and make sure that the Drive
58
indicated in the photo.
Vacuum off the dust when cleaning the
filter.
plate into the opening of the Drive unit
in the direction shown by arrow (a).
direction shown by arrow (b) until they
make a clicking sound to secure the inlet
plate.
Make sure that the plate is mounted
properly.
unit starts properly without any vibration or abnormal noise.