3.2.3 Install inside a Cabinet
When installing the Drive Unit inside a Cabinet, make sure to satisfy the condition
indicated in 3.2.1 Environment, 3.2.2 Installation and also the following conditions.
- The distance from the mounting surface and the inside of the door must be 220 mm or
more (190 mm when using the option I/O connector).
* When using the I/O connector (option), 190 mm or more
- Set the temperature inside the Drive Unit box to 40 deg.C or less by referring the cooling
method in the following example.
RC620DU Rev.5
220 mm
or more*
Mounting
Surface
Drive unit
Air Filter
Setup & Operation 3. Installation
Fan
I/O Connector (Option)
Product No: R12B040710
21