EDITION 12/ 2008
OPERATING MANUAL
8.3
EXCHANGE OF COMPLETE VALVE ROD
Unsuitable tool!
Damage to seals and sealing surfaces
Do not hold the valve rod with pliers or a similar tool.
SIHI_0006_GB
1. Closing down and cleaning
2. Unscrew tension nut (X), and remove compression spring (U).
3. Unscrew locking piece (Y) using spanner, size 17.
4. Remove sealing screw (4) using spanner, size 6, from the paint seal housing (9).
5. Carefully pull out complete valve rod using surface (D) – replace if necessary.
6. Reassemble in reverse order – do not forget to screw in the centre packing screw (4).
Put locking nut (X) and compression spring in place and tighten by hand.
PART NO. 350741
CAUTION
GA 2000EAC, GA 2005EAC
37