Updating the Firmware with the Bootloader
If power is lost while the Smart Camera Update is in progress, the Smart Camera
will not boot when power is restored. When this occurs, you will need to use the
Bootloader application in Non-Volatile memory (which is not erased by the
Smart Camera Update utility) to update the firmware.
Use the following procedure to update the firmware on your SIMATIC
HawkEye™ 1600T Smart Camera with the Bootloader:
Start a HyperTerminal session with the following settings:
1.
FIGURE E–2.
Click OK.
2.
While you hold down the Escape key, cycle power on the SIMATIC
3.
HawkEye™ 1600T Smart Camera. Information similar to the following is
displayed:
Rev. 1E, Nov 2007
Updating the Firmware with the Bootloader
COM1 Settings
SIMATIC HawkEye™ 1600T Smart Camera Guide
E
E-3