Siemens SIMATIC HawkEye 1600T Series Manual page 47

Smart camera
Table of Contents

Advertisement

Notes:
Bipolar isolated current input 5-24V, 1-5ma., 60 VAC isolation:
1.
Bipolar isolated output switch, Ron = 35 ohm max., Ion < 20ma.,
2.
Voff < µ±30VDC, 60VAC isolation (short circuit protected: 160-240 ma pk.)
with respect to GPIO Out Com.
Serial communication Transmit signal (RS-232)
3.
Serial communication Receive signal (RS-232)
4.
Common wire for General Purpose I/O opto-isolated outputs.
5.
Common wire for General Purpose I/O opto-isolated inputs.
6.
Rev. 1E, Nov 2007
Logic 0: 0 to 5V with respect to GPIO In Com
Logic 1: 15 to 30V with respect to GPIO In Com
Rin: 18k Ohms with respect to GPIO In Com
SIMATIC HawkEye™ 1600T Smart Camera Guide
HawkEyeTM 1600T Connectors
A
A-5