Simatic Hawkeye™ 1600T Connection Matrix - Siemens SIMATIC HawkEye 1600T Series Manual

Smart camera
Table of Contents

Advertisement

is described in Appendix E, "Updating Firmware on 1600T Cameras," as many
unique and useful parameters can only be changed using this method.
SIMATIC HawkEye™ 1600T Connection Matrix
Table D–1 describes the various options such that the Camera and PC can
communicate fully over TCP/IP.
TABLE D–1.
Camera
Host PC
DHCP
DHCP
DHCP
DHCP
Static
Static
To check a camera IP address, simply select the camera in Simatic FrontRunner
Network Overview.
To check a host PC IP address1:
At the DOS prompt, type:
1.
ipconfig
Rev. 1E, Nov 2007
SIMATIC HawkEye™ 1600T Connection Matrix
IP Addresses
DHCP
on LAN?
Action
Yes
Both get IP addresses from
Server
No
Camera and Host may fall over
to compatible IP Addresses
(169.254.x.x) (255.255.0.0)
(Automatic Private IP
Addressing (APIPA))
N/A
Camera and Host must be set to
compatible static IP address.
Default static IP for camera (as
delivered) is: 192.168.254.3.
Set PC to (for example)
192.168.254.2.
Both on (255.255.255.0) subnet.
SIMATIC HawkEye™ 1600T Smart Camera Guide
Connection
Yes
Maybe. Not all PCs
will default to
(169.254.x.x).
Some will default to
(0.0.0.0) – set static
IP on PC to APIPA
address (169.254.x.x
255.255.0.0).
Yes if IP Addresses
are compatible.
D-3
D

Advertisement

Table of Contents