5.7.2 To install the air conductor
1. Put the cables of the microswitch in a curve (A)
adjacent to the motor.
B
2. Connect the cables to the terminals (B) of the
microswitch.
3. Install the air conductor and attach the screw.
Note: Make sure that the cables of the microswitch
are between the motor and the cable holder.
18 - Repair instructions
A
5.8 Cutting unit
5.8.1 To remove the gear package
1. Disconnect the motor cables. Refer to
and connect the motor cables on page 17 .
2. Remove the air conductor. Refer to
air conductor on page 17 .
3. Remove the lower gear package cover.
4. Disconnect the transport mode sensor.
To disconnect
To remove the
1235 - 001 -