5.5
Push buttons
B1 USER: the user button is connected to the I/O PC13 (pin 2) of the STM32
microcontroller.
B2 RESET: this push button is connected to NRST, and is used to RESET the STM32
microcontroller.
Note:
The blue and black plastic hats that are placed on the push buttons can be removed if
necessary, for example when a shield or when an application board is plugged on top of
NUCLEO. This will avoid pressure on the buttons and consequently a possible permanent
target MCU RESET.
5.6
JP6 (IDD)
Jumper JP6, labeled IDD, is used to measure the STM32 microcontroller consumption by
removing the jumper and by connecting an ammeter.
•
Jumper ON: STM32 microcontroller is powered (default).
•
Jumper OFF: an ammeter must be connected to measure the STM32 microcontroller
current. If there is no ammeter, STM32 microcontroller is not powered.