gefran GFX4 Configuration And Programming Manual page 37

4-zone modular power controller
Hide thumbs Also See for GFX4:
Table of Contents

Advertisement

166
rL. 3
170
rL. 4
171
rL. 5
172
rL. 6
Read state
308
319
12
STATE rL.1
bit
13
STATE rL.2
bit
14
STATE rL.3
bit
15
STATE rL.4
bit
16
STATE rL.5
bit
17
STATE rL.6
bit
Allocation of physical outputs
607
ovt. 1
608
ovt. 2
609
ovt. 3
610
ovt. 4
611
ovt. 5
612
ovt. 6
613
ovt. 7
614
ovt. 8
615
ovt. 9
616
ovt. 1 0
80397M_MSW_GFX4-GFXTERMO4_08-2018_ENG
R/W
Allocation of reference signal
R/W
Allocation of reference signal
R/W
Allocation of reference signal
R/W
Allocation of reference signal
State of outputs rL.x MASKOUT
R
OFF = Output off
R
ON = Output on
OFF = Output off
R
ON = Output on
OFF = Output off
R
ON = Output on
OFF = Output off
R
ON = Output on
OFF = Output off
R
ON = Output on
OFF = Output off
R
ON = Output on
Allocation of physical output OUT 1
R/W
Allocation of physical output OUT 2
R/W
Allocation of physical output OUT 3
R/W
Allocation of physical output OUT 4
R/W
Allocation of physical output OUT 5
R/W
R/W
Allocation of physical output OUT 6
R/W
Allocation of physical output OUT 7
R/W
Allocation of physical output OUT 8
Allocation of physical output OUT 9
R/W
Allocation of physical output OUT 10
R/W
2 AL1 - alarm 1
3 AL2 - alarm 2
4 AL3 - alarm 3
5 AL.HB or POWER_FAULT with HB alarm (TA1 OR TA2 OR TA3)
6 LBA - LBA alarm
7 IN1 - repetition of logic input DIG1
8 AL4 - alarm 4
9 AL1 or AL2
10 AL1 or AL2 or AL3
11 AL1or AL2 or AL3 or AL4
12 AL1 and AL2
13 AL1 and AL2 and AL3
14 AL1 and AL2 and AL3 and AL4
15 AL1 or AL.HB or POWER_FAULT with HB alarm (TA1 OR TA2 OR TA3)
AL1 or AL2 or (AL.HB or POWER_FAULT) with HB alarm (TA1 OR TA2
16
OR TA3)
17 AL1 and (AL.HB or POWER_FAULT) with HB alarm (TA1 OR TA2 OR TA3)
AL1 and AL2 and (AL.HB or POWER_FAULT) with HB alarm (TA1 OR TA2
18
OR TA3)
19 AL.HB - HB alarm (TA2)
20 AL.HB - HB alarm (TA3)
21 Setpoint power alarm
22 AL.HB - HB alarm (TA1)
23 POWER_FAULT
24 IN2 - repetition of logic input DIG2
29 Communication error
+ 32 for denied logic level at output
+ 128 to force output to zero
Table of output states
bit
0
State rL.1
1
State rL.2
2
State rL.3
3
State rL.4
4
State rL.5
5
State rL.6
Table of output allocations
0
Output disabled
1
Output rL.1 zone 1
2
Output rL.1 zone 2
3
Output rL.1 zone 3
4
Output rL.1 zone 4
5
Output rL.2 zone 1
6
Output rL.2 zone 2
7
Output rL.2 zone 3
8
Output rL.2 zone 4
9
Output rL.3 OR rL.5 zone 1
10
Output rL.3 OR rL.5 zone 2
11
Output rL.3 OR rL.5 zone 3
12
Output rL.3 OR rL.5 zone 4
13
Output rL.4 AND rL.6 zone 1
14
Output rL.4 AND rL.6 zone 2
15
Output rL.4 AND rL.6 zone 3
16
Output rL.4 AND rL.6 zone 4
17
Output (rL.3 OR rL.5) zone 1...zone 4
18
Output (rL.4 AND rL.6) zone 1...zone 4
+32 to reverse output status only for Logic and Relay output
NOTE: In 3-phase configuration, the state of physical output OUT1 is copied to
OUT2 and OUT3. In 2-phase configuration, the state of physical output OUT1
is copied to OUT2 and the state of physical output OUT3 to OUT4
In case of COOL OUTPUT (5,6,7,8) are continuous, the same output functions
can not be used on other outputs.
Ex: If out. 1 = 1 (out rL. 1 zone 1) it is not possible to set out. 5 with the same
code, if out. 5 is continuous
2
35
4
160
1
2
3
4
5
6
7
8
17
18
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gfxtermo4

Table of Contents