FIGURE 16. LS STEER Hose Connected to Machine's Load Sense Hose
2. Install a -6 ORFS M/M straight adapter fitting (P/N 333-0012-033) on the end of the machine's load sense hose.
3. Install one end of the supplied hydraulic hose (P/N 214-1000-989) on the fitting installed on the load sense
hose.
FIGURE 17. LS STEER Hose Connected to SmarTrax Valve
4. Connect the other end of the installed hydraulic hose to the fitting installed in Port LS STEER of the SmarTrax
valve (P/N 334-0003-089).
Manual No. 016-5031-006 Rev. B
HYDRAULIC SYSTEM INSTALLATION
17