Table 5: Environmental Conditions

Storage
IEC 60068-2-1 60068-2-2
Temperature
-40°C to +85°C
Operating
IEC 60068-2-1 60068-2-2
Temperature
-40°C to +85°C for Extended Consumer Variants
0°C to +60°C for Commercial Temperature Variants
Humidity
IEC 60068-2-78
50% to 95% Relative Humidity at 25°C to 30°C, non- condensing
RoHS
RoHS II compliant
REACH Compliance
Regulation (EC) No 1907/2006
EMC and EMI
EN55022 [Must compliance with no deviation allowed] Class B radiated and conducted
EN 61000-6-3:2007 [Must compliance with no deviation allowed]
(EMC) Generic emission standard Part 6-4: Emission standard for commercial
environments
IEC 61000 PT4-2, (EN 61000-4-2) Electrostatic discharge immunity ESD
IEC 61000 PT4-3, (EN 61000-4-3 and ENV 50204) Radiated
Field
IEC 61000 PT4-4, (EN 61000-4-4) Electrical fast transient/burst (EFT) BURST
IEC 61000 PT4-5, (EN 61000-4-5) Surge immunity test
IEC 61000 PT4-6, (EN 61000-4-6) Immunity to conducted disturbances
IEC 61000 PT4-8, (EN 61000-4-8) Immunity to magnetic fields (LOW)
IEC 61000 PT4-11, (EN 61000-4-11) Testing and measuring techniques-voltage dips, short
interruption, and voltage variations immunity tests
Safety
EN 62368-1
Safety for information technology equipment including electrical business equipment
Altitude
2000m max
Shock
IEC 60068-2-27
Half-sine wave, Acceleration: 2g Pulse duration: 11ms
Number of shocks: 600 shocks (100 shocks for each face)
Vibration
IEC 60068-2-64
Test Fh, Random Vibration, 90 min per axis, 3 axes at 1.9 grms, with PSD: 10-20Hz: 0.05
g²/Hz and 20-500 Hz:- 3dB/octave.
Reliability
5 years x 365 days x 24 hours
including MTBF
The MTBF value according to Telcordia standard
Power Supply Specifications
Voltage Ripple
Voltage Ripple maximum 100 mV peak to peak 0-20 MHz
Rise Time
2 ms to 20 ms rise time from input voltage <10% to nominal VCC
If any of the supply voltages drops below the allowed operating level longer than the
specified hold-up time, all the supply voltages should be shut down and left OFF for a time
long enough to allow the internal board voltages to discharge sufficiently.
If the OFF time is not observed, parts of the board or attached peripherals may work
incorrectly or even suffer a reduction of MTBF.
The minimum OFF time depends on the implemented PSU model and other electrical factors