Rescue Process Activation/End - Axis 2N LiftIP User Manual

Communicator for lifts
Hide thumbs Also See for 2N LiftIP:
Table of Contents

Advertisement

4.6 Rescue Process Activation/End

Rescue Process Activation
Set parameter 992 (rescue password) to activate the rescue process. If an alarm call is
set up, the yellow LED keeps shining on the audio unit after the call end to indicate the
rescue process activation.
Rescue Process End
Call the CU (9 for administration – 2 for rescue end – enter password) to deactivate
the rescue process.
The audio unit announces "Rescue process ended" when the rescue process is
completed.
Event after Rescue End
An event can be made when the rescue process has been ended.
operational calls only.
Operational call – the call is set up to the number set in parameters 081–088
(operational call) and transmitted via CPC Antenna, CPC KONE or P100.
Set the parameters via the Service Tool (Events – Button stuck).
Parameter 990
From version 2.5.0 up, you can set operational calls (Audio error, Audio fixed) via
parameter 990. Refer to Subs.
Caution
If set via parameter 990 and the Event menu (script), the operational
call will be set up twice.
2N TELEKOMUNIKACE a.s., www.2n.cz
3.2 (Table of Parameters)
®
2N
LiftIP
for details.
supports
82/117

Advertisement

Table of Contents
loading