Technical Data; Connection Diagram; Wiring Schemes - Danfoss MCV104A Manual

Electrical displacement control
Table of Contents

Advertisement

TECHNICAL DATA

ELECTRICAL
NOMINAL START CURRENT
± 11 mA (single coil)
± 16 mA (using one of the dual coils)
± 8 mA (using the dual coils in series)
± 16 mA (using the dual coils in parallel)
± 6.25 mA (low current models)
NOMINAL FULL STROKE CURRENT
(See Current vs. Swashplate Angle and Wiring Schemes)
85 ± 12 mA (single coil)
125 ± 18 mA (using one of the dual coils)
62 ± 9 mA (using the dual coils in series)
125 ± 18 mA (using the dual coils in parallel)
18 ± 1.5 mA (low current models)
Current tolerances include ± 5 mA for single coil and ±
pump series' . For sizing drive sources, use 100 mA in compu-
tations for single coil EDC's.
COIL RESISTANCE @ 24° C (76° F)
23 ohms (single coil)
19.5 ohms (A, B Terminals),
15.5 ohms (C, D Terminals) (dual coil)
650 ohms (low current models)
COIL RESISTANCE @ 104° C (220° F)
29 ohms (single coil)
24.7 ohms (A, B Terminals),
19.7 ohms (C, D Terminals) (dual coil)
800 ohms (low current models)
COIL INDUCTANCE
.14 henries (single coil)
.062 henries (A, B Terminals),
.047 henries (C, D Terminals) (dual coil)
MAXIMUM CONTINUOUS VOLTAGE @ 93.3° C(200° F)
7.5 Vdc for single coil models with the exceptionof those
low current models
14 Vdc for dual coil models in series
7.5 Vdc for dual coil models when only one coil or both coils
in parallel are used
24 Vdc for low curent models.
The EDC is designed to be controlled from a dc current source or
voltage source. Pulse width modulation (PWM) is not required.
But if a PWM signal is used, avoid a carrier frequency <200 Hz.
Do not use a pulse current of more than 120% of that required
for full output.
HYDRAULIC
OIL VISCOSITY
40 - 6000 SSU
OIL TEMPERATURE
- 40° C (- 40° F) minimum
+ 104° C (+220° F) maximum continuous
+ 116° C (+240° F) maximum intermittent
AMBIENT OPERATING TEMPERATURE
- 40° to 93° C (- 40° to 200° F)
© Danfoss, 2013
CURRENT VS. SWASHPLATE ANGLE
80 mA
60 mA
INPUT CURRENT (MA)
Current Vs. Swashplate Angle for the MCV104A.
Single-Coil Load Pressure is 3000 PSI and Current Input is 0.01
Hz.

CONNECTION DIAGRAM

Pin Orientation of 4-pin, 90° MS Mating Connector. Part
No. MS3108E-14S-2S (Sauer-Danfoss Kit No. K08106).

WIRING SCHEMES

+A
700
B
SINGLE COIL 20 MA
WITH 15 VDC
INPUT AT FULL STROKE.
(LOW CURRENT MODEL)
A
+
B
C
D
DUAL COILS IN SERIES,
62 MA WITH 2.2 VDC
INPUT AT FULL STROKE.
K07116 • Rev AB • September 2013
18∞
15∞
10∞
5∞
40 mA
20 mA
20 mA
5∞
10∞
15∞
18∞
D
A
C
B
+A
24
B
SINGLE COIL 85 MA
WITH 2.0 VDC
INPUT AT FULL STROKE.
USING ONE OF THE TWO DUAL COILS ,
125 MA WITH 1.9 VDC (C, D COIL) OR
2.4 VDC (A, B COIL)
INPUT AT FULL STROKE.
A
+
35 Ω
9 Ω
(TOTAL
(TOTAL
B
RESISTANCE)
RESISTANCE)
C
D
DUAL COILS IN PARALLEL,
125 MA WITH 1.1 VDC
INPUT AT FULL STROKE.
40 mA
60 mA
80 mA
1141
1276
+A
19.5
B
+C
15.5
D
1300
5

Hide quick links:

Advertisement

Table of Contents
loading