REPLACING V7058 WITH MCV104 FOR S20 PV
Replacing the V7058A1296 hydrotransmission valve with the
MCV104 EDC valve is acceptable and often recommended. The
MCV104xxxxx can be mounted directly in place of the V7058
without changing the pump drag link. The EDC operates with
lower electrical current and voltage, therefore a 50 to 75 ohm 3
Watt resistor must be placed in series to the EDC. The current/
voltage used for the V7058 will be reduced from approximately
250 mA at 9.0 Volts to 130 mA at 2.6 Volts for dual coil EDC, and
90 mA at 2.3 Volts for single coil EDCs. If a single coil EDC is used,
select a 75 ohm 3 Watt resistor. When using a dual coil EDC, select
a 50 ohm 3 Watt resistor.
PARTS DESCRIPTION
Resistor, 50-ohm 3-Watt (if using the dual coil model)
Resistor, 75-ohm 3-Watt (if using the single coil model)
ADDITIONAL PARTS
EDC installation kit (i.e., 23 frame size and non-POR)
Mating electrical connector, if Packard for dual coil EDCs
If the EDC is to be the standard or most common, but may
require the dual coil with the Packard connector
CROSS REFERENCE FOR SEREIES 20 EDC PART NUMBERS
CURRENT PART NUMBER
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
MCV104A
© Danfoss, 2013
V7058
(if needed)
Description
5 9 2 2 Single Coil Packard
5 9 2 3 Dual Coil Packard
5 9 2 6 Single Coil MS
5 9 2 7 Dual Coil MS
6 9 2 2 Single Coil Packard
6 9 2 3 Dual Coil Packard
6 9 2 6 Single Coil MS
6 9 2 7 Dual Coil MS
7 9 2 2 Single Coil Packard
7 9 2 3 Dual Coil Packard
7 9 2 6 Single Coil MS
7 9 2 7 Dual Coil MS
8 9 2 2 Single Coil Packard
8 9 2 3 Dual Coil Packard
8 9 2 6 Single Coil MS
8 9 2 7 Dual Coil MS
K07116 • Rev AB • September 2013
The electrical connection is accomplished through two wires with
the V7058 or EDC. The EDC can be either a single coil (coil A/B)
or dual coil (coils A/B and C/D). If a dual coil EDC is used only the
A and B pin connections are required for operation.
fying the switching function for FWD and REV of the pump if just
a potentiometer is used, i.e., A/B coil for FWD and C/D for REV.
MCV104
PART NUMBER
K04139
K04144
KK04123
K03384
MCV104A5923
REPLACES PART NUMBER
MCV104A
1 or 5
0 thru 9
MCV104A
1 or 5
0 thru 9
MCV104A
1 or 5
0 thru 9
MCV104A
1 or 5
0 thru 9
MCV104A
2 or 6
0 thru 9
MCV104A
2 or 6
0 thru 9
MCV104A
2 or 6
0 thru 9
MCV104A
2 or 6
0 thru 9
MCV104A
3 or 7
0 thru 9
MCV104A
3 or 7
0 thru 9
MCV104A
3 or 7
0 thru 9
MCV104A
3 or 7
0 thru 9
MCV104A
4 or 8
0 thru 9
MCV104A
4 or 8
0 thru 9
MCV104A
4 or 8
0 thru 9
MCV104A
4 or 8
0 thru 9
-
0
1 or 2
0
3 or 4
0
5 or 6
0
7 or 8
0
1 or 2
0
3 or 4
0
5 or 6
0
7 or 8
0
1 or 2
0
3 or 4
0
5 or 6
0
7 or 8
0
1 or 2
0
3 or 4
0
5 or 6
0
7 or 8
15