WIRING ( continued)
5.
The distance from the back of the tangs to the furthest rib
may not exceed 19.5 millimeters. See Distance, Packard
Connector diagram.
6.
Manually insert the assembled wires into the back end
(large hole) of the plastic housing. Push until the wire de-
tents with an audible click, then pull back slightly to ensure
proper seating. (Observe the proper phasing of the wires
when installing: Black wire to "A" hole, Red to "B" , Black to
"C" and Red to "D" .) Terminals may be removed from the
connector bodies with a Packard 12014012 removal tool.
DIMENSION A.
DIMENSION
A
DIS TANCE, PACKARD CONNEC TOR
CONNEC TOR PARTS IDENTIFIE D, PACKARD CONNEC TOR
© Danfoss, 2013
Dimension A For Selecting Correct Terminal.
Distance From Tang to Third Rib of Packard Connector.
SIDE "B"
CABLE
SEALS
TOWER CONNECTOR
K07116 • Rev AB • September 2013
7.
Swing the holder down into the detented position to trap
the wires in the housing. The third rib should be sealed into
the housing.
8.
Plug the shroud connector from the valve into the tower
connector just constructed. They are sealed with a double
(or quadruple) plug seal over the double (or quadruple)
barrel of the tower assembly. The two connector halves
should detent into each other. See Connector Parts Identi-
SIDE "A"
SHROUD
CONNECTOR
DOUBLE-PLUG
SEAL
1123
1077A
1078A
10