Emerson AMS Wireless Vibration Monitor User Manual page 68

Table of Contents

Advertisement

Specifications and reference data
August 2020
Table A-5: Z Overall
Axis
Z Overall
Z Overall
Z Overall
Z Overall
Z Overall
Table A-6: Z Peakvue
Axis
Z Peakvue
Z Peakvue
Z Peakvue
Z Peakvue
Z Peakvue
Z Peakvue
Z Peakvue
Z Peakvue
Table A-7: IB1 Velocity
Axis
IB1 Velocity
IB1 Velocity
IB1 Velocity
IB1 Velocity
IB1 Velocity
IB1 Velocity
IB1 Velocity
68
(continued)
Severity
Upper Limit
Sensor
70
Range
5
Fail
1
Maint
0.35
Advise
0.14
Severity
Upper Limit
Error
Not Applicable Not Applicable 250
Unused
Not Applicable Not Applicable 250
Saturated
100
Sensor
100
Range
100
Fail
40
Maint
20
Advise
10
Severity
Upper Limit
Unused
Not Applicable Not Applicable 250
Saturated
70
Sensor
70
Range
5
Fail
0.6
Maint
0.21
Advise
0.084
Lower Limit
Units
0
in/s
0
in/s
0
in/s
0
in/s
0
in/s
Lower Limit
Units
0
g
0
g
0
g
0
g
0
g
0
g
Lower Limit
Units
0
in/s
0
in/s
0
in/s
0
in/s
0
in/s
0
in/s
MHM-97927-PBF, Rev 1
User Guide
MHM-97927-PBF
Notes
Read-only
Can be set by
the user up to
the sensor
range
Notes
Read-only
Read-only
Can be set by
the user up to
the sensor
range
Notes
Read-only
Read-only
Can be set by
the user up to
the sensor
range

Advertisement

Table of Contents
loading

Table of Contents