Overall Velocity, PeakVue, and temperature
August 2020
Table 5-2: Default velocity levels in AMS Wireless Vibration Monitor
Alert level
Maintenance
Failed
5.2

PeakVue

PeakVue
frequency phenomena associated with developing faults, especially in rolling-element
bearings.
The premise for PeakVue is that the high-frequency components are not readily detected
with more conventional measurements such as Overall Velocity, low-frequency energy
(LFE), or digital overall. This is because the low-frequency measurements either average
the energy or provide an energy summation over a relatively large frequency band, and
the relative amount of energy that is typically contributed by the high-frequency
components is quite small. As a result, even large "spikes" are difficult to detect with classic
techniques.
The difference in the vibration waveform and the associated measurement for overall
vibration versus PeakVue is shown in
below the established advisory and maintenance alert levels indicating that the machine is
running well. In contrast, the PeakVue graph shows that the values have increased from
zero, and that they are already crossing the advisory alert level and approaching the
maintenance alert level. This early warning about impending defects is key to maintaining
good machine health.
The PeakVue algorithm isolates the peak energy of interest to provide early indications of
developing bearing faults such as inner and outer race defects, ball defects, and
lubrication problems. Any type of "impacting" fault, where metal is contacting metal, is
readily visible with PeakVue long before there is any significant increase in Overall
Vibration. PeakVue is especially useful for monitoring rolling-element bearings.
Figure 5-4
PeakVue.
Figure 5-4: PeakVue advisory levels
58
is a patented Emerson technology that is very useful for isolating high-
shows an example of a typical formula for calculating the advisory alert level for
Velocity (in RMS)
0.35 in/s
1.0 in/s
Figure 5-5
and
Figure
5-6. The overall vibration is well