Physical Specifications; Performance Specifications - Emerson AMS Wireless Vibration Monitor User Manual

Table of Contents

Advertisement

Specifications and reference data
August 2020
A.2

Physical specifications

Battery
Table A-1: Tadiran Lithium Batteries Model TL-4920/VE
Nominal capacity @ 3 mA, to 2 V
Rated voltage
Maximum recommended continuous current
Maximum 1 sec. pulse capability
Weight
Volume
Operating temperature range
U.L. Component Recognition, MH 12193
Field Communicator connections
HART ports
Clips attached to the HART ports
Mounting
Mounting tools and supplies depend on the mounting mechanism. For more information,
see
Mounting tools and
Mounting screw thread is 1/4 - 28
Weight
0.697 lb (315 g)
Enclosure ratings
Housing is NEMA 4X and IP66
A.3

Performance specifications

Temperature Limits
The device is rated for operation in the range from -40 to +85C.
Table A-2: Temperature limits
Device
AMS Wireless Vibration
Monitor
66
8.5 Ah
3.6 V
75 mA
200 mA
49.5 g (1.746 oz)
26 cc
-55 ºC to +85 ºC
supplies.
Operating limit
-40 to +85C
User Guide
MHM-97927-PBF
Storage limit
-55 to +85C
Note
Prolonged storage above +75 C
degrades battery life
MHM-97927-PBF, Rev 1