Service Required Errors; Error Log Codes - Frymaster BIGLA30 Series Service Manual

Lov gas
Hide thumbs Also See for BIGLA30 Series:
Table of Contents

Advertisement

5. The computer displays CLEAR PASSWORDS on the left and COMPLETE on the right. This clears any
passwords set up under levels one and two.
Press the button to toggle to FILTER PAD TIME on the left and 25 on the right. (25 hours is the default
6.
time to change the pad)
Press the  (2) button to accept changes and exit.
7.
8.
The computer displays OFF.

1.17.4 Service Required Errors

A SERVICE REQUIRED error alternating with YES displays on the computer. After YES is pressed the alarm is
silenced. The computer displays an error message from the list below three times with the location of the error.
Then the computer displays SYSTEM ERROR FIXED? YES/NO. If yes is chosen, enter code 1111. If NO is
chosen the system returns to cook mode for 15 minutes then redisplays error until issue is fixed.
Pressing the MIB reset button during any filter function will generate a "SERVICE REQUIRED" error.

1.17.5 Error Log Codes

Refer to page 1-49, level 2 program for access to the E-log. The ten most recent errors are listed from A-
J, with A being the most recent error.
Code
ERROR MESSAGE
E03
ERROR TEMP PROBE FAILURE
E04
HI 2 BAD
E05
HOT HI 1
E06
HEATING FAILURE
E07
ERROR MIB SOFTWARE
E08
ERROR ATO BOARD
E09
ERROR PUMP NOT FILLING
E10
ERROR DRAIN VALVE NOT OPEN
E11
ERROR DRAIN VALVE NOT CLOSED
E12
ERROR RETURN VALVE NOT OPEN
E13
ERROR RETURN VALVE NOT CLOSED
E14
ERROR AIF BOARD
E15
ERROR MIB BOARD
E16
ERROR AIF PROBE
E17
ERROR ATO PROBE
E19
M3000 CAN TX FULL
E20
INVALID CODE LOCATION
E21
FILTER PAD PROCEDURE ERROR (Change
Filter Pad)
E22
OIL IN PAN ERROR
E23
CLOGGED DRAIN (Gas)
E24
OIL SENSOR FAILED (Gas)
E25
RECOVERY FAULT
EXPLANATION
Temp probe reading out of range
High limit reading is out of range.
High limit temperature is past more than 410°F
(210°C), or in CE countries, 395°F (202°C)
A component has failed in the high limit circuit such
as computer, interface board, contactor or open-high
limit.
Internal MIB software error
MIB detects ATO board connection lost; ATO board
failure
Oil not returning to vat quickly. Possible problems:
dirty pad, bad or missing O-rings, tripped or defective
filter pump, actuators or linkage.
Drain valve failed to open; the valve's position is
unknown.
Drain valve failed to close; the valve's position is
unknown.
Return valve failed to open; the valve's position is
unknown.
Return valve failed to close; the valve's position is
unknown.
MIB detects AIF missing; AIF board failure
Cooking computer detects MIB connections lost;
Check software version on each computer.
versions are missing, check CAN connections
between each computer; MIB board failure
AIF RTD reading out of range
ATO RTD reading out of range
Connection between computers lost
SD card removed during update
25 hour timer has expired or dirty filter logic has
activated
The MIB has reset the oil in pan flag.
Vat did not empty during filtration
Oil is back sensor failed.
Recovery time exceeded maximum time limit.
1-46