Connection module

Advertisement

Quick Links

IndraControl VAC 31
Connection Module
24. Januar 2011
.1
Assembly Instruction
Page 1 of 8
Bosch Rexroth AG
Electric Drives and Controls
Bgm.-Dr.-Nebel-Str. 2
D-97816 Lohr am Main
Phone +49 (0)9352-40-50 60
Fax +49 (0)9352-40-48 85
www.boschrexroth.com
R911333527-AA_BPZ_DOC

Advertisement

loading

Summary of Contents for Bosch Rexroth IndraControl VAC 31

  • Page 1 Bosch Rexroth AG Electric Drives and Controls Bgm.-Dr.-Nebel-Str. 2 D-97816 Lohr am Main Phone +49 (0)9352-40-50 60 Fax +49 (0)9352-40-48 85 www.boschrexroth.com IndraControl VAC 31 Connection Module Assembly Instruction Page 1 of 8 24. Januar 2011 R911333527-AA_BPZ_DOC...
  • Page 2: About This Document

    About this Document assembly instructions describe how to install the IndraControl VAC 31.1 Connection Module. For further information, please refer to the pr oject planning manual “Rexroth Indra¬Control VCH 08.1”, parts number R911320190 or “Rexroth IndraControl VEH 30.2”, parts number R911331585. Symbols his document uses the following symbols to draw the reader’s attention to notices and dangers:...
  • Page 3 Also check, whether the delivery corresponds to the data on the delivery note. Please contact the Bosch Rexroth sales department immediately in case of discrepancies or damages in transit. Assembly...
  • Page 4 The voltage is supplied via the plug-in connector X1.1 or X1.2. This device is quipment of protection class I. To operate the device safely, a PELV corre- sponding to DIN EN 61131 has to be used as supply voltage. A cable w ith fine wire cable cores with a minimum cross section of 0.75 m²...
  • Page 5: Connecting The Hand Held Terminal

    Pin assignment Connection parameters Signal name Parameters Value put fuse is triggered. X1.2 Pin4 Terminal connected OUT X2.1 Pin1 E-STOP button 1 IN The connection module IndraControl VAC 31.1 is sup- plied with voltage via X1.1 pin1 or X1.2 pin1. The con- X2.1 Pin2 E-STOP button 1 OUT nected handheld terminal is supplied with voltage via X1.1 pin3 or X1.2 pin3.
  • Page 6 Before commissioning the hand-held terminal, please ensure tha e STOP button is NOT pressed. Connecting the hand-held termi- nal during a pressed STOP button will shut the installation down. To connect the hand-held terminal, place the angled connector with little force, at an angle of approximately 45°, on the flange of the IndraControl VAC 30.2.
  • Page 7 To ensure the optimal connection of the contacts and to achieve the specified degree of protection, the knurled nut has to be screwed on until the fixed stop is reached. To disconnect the hand-held terminal, unscrew the panel connector and place the short-circuit-connector on the flange of the connection module IndraControl VAC 31.1 with little force.
  • Page 8 The short-circuit connector closes the E-Stop circuits in case no and-held terminal is plugged on. An open flange will shut down the installation. Seite 8 von 8 24. Januar 2011 R911333527-AA_BPZ_DOC...