Changing jobs (loading another job)

The following shows the procedure to load the job file "1Test".
The number '1' prefixed to the file name indicates an ID. By setting this ID number to 'Command' (W1000) of a remote resister
(RWw), the job ("1Test") can be loaded.
Set a device value in the "Device/Buffer Memory Batch Monitor" window in GX Works3.
1.
Set an ID number of a job.
Ò
2.
Change jobs (load another job).
Ò
Õ
Ö
To load a job, the file name of the job need to begin with an ID number.
When loading a job, make a vision sensor offline.
Ô
Ó
Ô
 Enter 'W1000' for "Device Name".
 Click the [Start Monitoring] button.
 Enter '1' for 'Command' (W1000) of
Ó
a remote register (RWw).
 Enter 'Y1000' for "Device Name".
 Turn ON 'Set Offline' (Y1007) of a
remote output to make the vision
sensor offline.
 Turn ON 'Execute Command'
(Y1004) of a remote output to load a
job.
 Enter 'X1000' for "Device Name".
 When the loading of the job is
completed, 'Command Completed'
(X100D) of a remote input is changed
(toggled). After that, turn OFF 'Execute
Command' (Y1004) and 'Set Offline'
(Y1007).