Enabling a trigger on the vision sensor

Enable a trigger on the vision sensor to acquire the inspection results.
Open [Online]  [Monitor]  [Device/Buffer Memory Batch Monitor] in GX Works3 to display device values.
1.
Display device values.
2.
Enable a trigger on the vision sensor.
3.
Trigger a device.
2 SLMP SCANNER CONNECTION
58
2.6 Checking Operations
Ò
Ò
Ò
 Enter "M0" for "Device Name".
 Click the [Start Monitoring] button.
Ó
 Turn "M0" ON to turn 'Trigger
Enable' (D1000.0) ON.
 Turn "M1" ON to turn 'Trigger'
(D1000.1) ON.