Remote I/O Signals (Rx/Ry); Remote Registers (Rwr And Rww) - Mitsubishi Electric VS20M-11F310 Connection Manual

Melsensor, fa sensor, vision sensor
Hide thumbs Also See for VS20M-11F310:
Table of Contents

Advertisement

Remote I/O signals (RX/RY)

The following shows the I/O signals for a master station (programmable controller) in a CC-Link IE Field Network Basic
connection.
The I/O signal assignment in the following tables is an example when the remote I/O signals of a vision sensor are assigned
for RX0 to RX3F and RY0 to RY3F.
For details on each data, refer to the help of In-Sight Explorer.
• Remote output (RY)
Remote output (RY) is a signal that is sent to a vision sensor from a mater station (programmable controller) used for the CC-
Link IE Field Network Basic connection.
RY7
RY6
Set Offline
Reserved
RYF
RYE
Reserved
RY17
RY16
Reserved
RY1F
RY1E
Soft Event 7
Soft Event 6
RY20..RY3F
User Data (Bit Area)
• Remote input (RX)
Remote input (RX) is a signal that is sent to a mater station (programmable controller) from a vision sensor used for the CC-
Link IE Field Network Basic connection.
RX7
RX6
Online
Offline Reason
RXF
RXE
Error
Command Failed
RX17
RX16
Reserved
RX1F
RX1E
Soft Event Ack 7
Soft Event Ack 6
RX20..RX3F
Inspection Results (Bit Area)

Remote registers (RWr and RWw)

The following shows the remote registers (RWr and RWw) used for the CC-Link IE Field Network Basic connection.
• Remote register (RWr)
RWr0
RWr1
Current Job ID
Error Code
• Remote register (RWw)
RWw0
Command
RY5
RY4
Execute
Command
RYD
RYC
RY15
RY14
RY1D
RY1C
Soft Event 5
Soft Event 4
RX5
RX4
RXD
RXC
Command
Command
Completed
Executing
RX15
RX14
Job Pass
RX1D
RX1C
Soft Event Ack 5
Soft Event Ack 4
RWr2
Acquisition ID
1.2 Basic Operations for a CC-Link IE Field Network Basic Connection
RY3
RY2
Inspection
Buffer Results
Results Ack
Enable
RYB
RYA
RY13
RY12
Clear Exposure
Clear Error
Complete
RY1B
RY1A
Soft Event 3
Soft Event 2
RX3
RX2
Missed Acq
Reserved
RXB
RXA
Results Valid
Results Buffer
Overrun
RX13
RX12
Exposure
Reserved
Complete
RX1B
RX1A
Soft Event Ack 3
Soft Event Ack 2
RWr3
RWr4
Inspection ID
Inspection Result Code
RWw1..
User Data
1 CC-Link IE Field Network Basic CONNECTION
RY1
RY0
Trigger
Trigger Enable
RY9
RY8
RY11
RY10
Reserved
Set User Data
RY19
RY18
Soft Event 1
Soft Event 0
RX1
RX0
Trigger Ack
Trigger Ready
RX9
RX8
Inspection
System Busy
Completed
RX11
RX10
Reserved
Set User Data
Ack
RX19
RX18
Soft Event Ack 1
Soft Event Ack 0
RWr5..
Inspection Results
1
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents