3.2.3. Operating components

1. Interval rotary-switch „TIME"
2. Push-button „CONNECT"
1. Interval rotary-switch "TIME"
With the rotary switch "TIME", the following transmission and measurement intervals can
be selected.
Attention:
With the webserver (EE242 Base Station), any time interval can be configured.
Selecting a time interval of less than 15 minutes for the transmitter will greatly reduce
the operating life of the batteries. Typical operating life is up to 3 years, based on a
transmission interval of 15 minutes (for T / %RH).
2. Push-button „CONNECT":
To establish the initial connection between the base station and the transmitter.
For a detailed technical description, see chapter 4.1. "Point-to-Point" (EE241 with a single
transmitter).
Additionally the status of "signal strength level [%]" can be activated temporary with this
key.
If you press the key for 1 sec while connecting the voltage supply (or the last battery is
inserted) the EE244 shows the "signal strength level [%] of the wirless connection for 60
sec before switching back to the normal display mode.
3. Display:
Place the display on the designated pins. Display symbols:
On the display all available measured values (RH, T, CO2) of the sensors
(up to 3) are alternatly indicated.
Warning: The measured values are updated in the adjusted interval „TIME"
(see chapter 3.2.3.1).
Switch position
0
1
2
3
4
5 = default
6
7
8
9
A
B
C
D
E
F
><
><
°C / °F Unit of the chosen temperature value
%RH
Interval
3 sec.
10 sec.
30 sec.
1 min.
2 min.
5 min.
10 min.
15 min.
20 min.
30 min.
45 min.
60 min. (1 hr)
90 min. (1.5 hr)
120 min. (2 hr)
180 min. (3 hr)
240 min. (4 hr)
This symbol is 'on' if the wireless connection is established
and 'blinks' if the connection fails.
Unit for rel. humidity (%RH)