Troubleshooting - Kessel Aqualift F Basic Installation And Operating Manual

Pumping station
Table of Contents

Advertisement

Available languages

Available languages

9

Troubleshooting

Error
No mains voltage available
Main power circuit breaker has tripped
Connection cable damaged
Pump is not running
Float switch defective
Overheating
Incorrect
Float switch blocked
level detected, level
error displayed
Multi-vane
Soiling, solids have become lodged between
impeller blocked
the multi-vane impeller and the spiral housing.
Intake cage blocked
Spiral housing is worn
Reduced performance
Multi-vane impeller worn
Ventilation pipe blocked
016-102_01 DE_EN_FR
Cause
Pumping station / Installation and operating manual
Remedial measures
Check mains voltage
Switch circuit breaker on again
Repair only by qualified electricians/service
partners
Contact Customer Services
Submersible pump switches back on again
automatically when the temperature has
dropped again
Carry out maintenance (see "Level measure-
ment", page 91)
Clean pump (see "Pump", page 89)
Clean pump (see "Pump", page 89)
Replace the spiral housing
Replace multi-vane impeller
Clean ventilation opening
93 / 144

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents