Circuit Breaker; Knife Replacement, Taping Head; Drive Belts; Replacement/Tension Adjustment - 3M -Matic 800asb Instructions And Parts List

Adjustable case sealer with accuglide ii std 1-1/2 inch taping heads
Hide thumbs Also See for 3M-Matic 800asb:
Table of Contents

Advertisement

Maintenance
(Continued)
WARNING – Turn off electrical power and disconnect power cord from electrical supply
before beginning maintenance. If power cord is not disconnected, severe injury to personnel
could result.

Circuit Breaker

The case sealer is equipped with a circuit breaker
which trips if the motors are overloaded. Located
inside the electrical enclosure on the right side of the
machine frame just below the machine bed, the
circuit breaker has been pre-set at 2.2 amps and
requires no further maintenance.
WARNING – The following
procedure must be performed by
trained service personnel because of the
high voltage electrical hazard within the
control box.
If circuit is overloaded and circuit breaker trips,
unplug machine from electrical power:
1. Determine cause of overload and correct.
2. Remove electrical enclosure cover.
3. Press the red "Reset" button and then the
green "Start" button.
4. Replace cover.
5. Plug in machine.
6. Press machine "On" button to resume case
sealing.
Figure 4-2 – Box Drive Belt (Left Side View – Infeed End)

Knife Replacement, Taping Head

See Section II, "Maintenance - Knife Replacement",
page 9.

Drive Belts

Note – 3M recommends the replacement of
drive belts in pairs, especially if belts are
unevenly worn.
REPLACEMENT – SEE STEPS 1 THRU 8
TENSION ADJUSTMENT – SEE STEPS 3, 7 AND 8
1. Crank the upper taping head to its fully raised
position.
2. Remove and retain the five screws (A), five
washers (B) and side cover (C). See Figure 4-2.
3. Remove and retain the screw (D), washer (E)
and belt tensioner cover (F).