【1】HOW TO USE THE THREAD TRIMMER
< Note >
Do not use this thread trimmer with no fabric under the presser foot.
■  P ressing the pedal with toe (position A) starts the
machine.
needle at the top/bottom of its stroke (adjustable with
the motor).
■  I f the needle stops at the bottom of its stroke as adjusted,
pressing the pedal with heel (position C) raises the
needle.
As soon as the needle stops at the top of its stroke by
pressing the pedal with heel, the thread trimmer gets
actuated (if the needle stops at the top of its stroke as
adjusted, the thread trimmer gets actuated by pressing
the pedal with heel).
■  R eturning the pedal to position B lowers the presser foot.
■  T he presser foot can be raised or lowered freely by releasing the pedal (position B) or
pressing the pedal with heel (position C) until the pedal is placed at position A for the
next sewing operation after the threads are cut.
【2】INSTALLING THE POSITION DETECTOR
■  I nstall position detector A and tighten screw B
temporarily.
■  F it positioner bar C onto the guide groove of the position
detector. Then tighten screw D.
■  T urn on the motor.
< Note >
Remove the connector for the thread trimmer cylinder.
Make sure the knife is retracted all the way.
■  P ress the pedal with heel after two to three stitches are
formed by pressing the pedal with toe.
Then the needle stops.
■  L oosen screws B for the position detector.
Turn the machine pulley while checking that the
position of screws B is not shifted.
handwheel E with the alignment mark on the arm.
Then the needle bar is at the top of its stroke.
Tighten screws B to secure the position detector.
■  C heck to see if the needle bar stops at the top of its
stroke by pressing and then releasing the pedal.
Releasing the pedal (position B) stops the
Align mark P on
1