IPMI
Sensor Name
Description (Sensor Type, Event trigger)
sensor
ID
25
Power Good
Actual RTM power good status
26
Pwr Good HD1
Actual HD1 power good status
27
Pwr Good HD2
Actual HD1 power good status
28
Health Error
General health status
X
Exceed critical threshold / Error Assertion
*
Power On/Off
-
Power On
N
No change
2.7.2.1
IPMB-L Link Sensor
The RTM806X has an IPMB-L link to communicate with the processor board and other devices in the chassis
chassis IPMB-0 bus. MMC monitors the bus for any link failure and sends the bus failure event to the front
board upon the recovery occurs.
2.7.3

Field Replaceable Unit (FRU) Information

The FRU Information provides inventory data about the boards where the FRU Information Device is located.
The part number or version number can be read through software.
FRU information in the RTM806X includes data describing the RTM806X board similar to AMC.0 R2.0
specification requirements. This information is retrieved by the RTM, enabling reporting of board-specific
information through a standardized mechanism.
Table 2-3:Board Information Area
Board Information Area
Field Description
Format Version
Board Area Length
Language code
Manufacturing Date / Time
Board Manufacturer type/length
Board Manufacturer
Board Product Name type/length
Board Product Name
Board Serial Number type/length
Board Serial Number
Board Part Number type/length
Board Customer Part Number
FRU File ID type/length
Value (hex)
0x01
*Calculated
0x00
*Based on mfg. date
*Calculated
"Kontron"
*Calculated
"RTM806X"
*Calculated
Manufacturer S/N
*Calculated
"T5707###_R"
*Calculated
11
Scanning En-
Health LED
abled under
(Green to Am-
Power State
ber)
-
X
-
X
-
X
*
N
RTM806X