ESTING
The cameras, inputs, and outputs are configured and tested using a MobileView Test Kit.
4.1
C
ONNECTING THE
See Figure 34 and perform the following:
1)
Remove the DVR from the outer housing and set it aside until testing is complete.
2)
Remove the back box from the outer housing.
3)
Plug the provided 10-foot (3 m) cable's Molex connector into the interface box ( ).
4)
Plug the Molex connector on the other end of the 10-foot (3 m) cable into the test kit ( ). If more
length is necessary, use the 50-foot (15 m) expansion cable ( ).
5)
Plug the interface box (label up) into the DVR through the edge connector ( ). If the green LED on
the interface box illuminates, skip to step 8. If the LED does not illuminate, proceed to step 6.
6)
If the green LED on the interface does not illuminate, unplug the four-pin Molex power connection
on the DVR and plug it into the receptacle end of the interface cable (
must be supplied to the DVR. Add a ferrite clamp ( ) to the 24 V power cable at the Molex
connector (J3).
7)
Plug the interface cable Molex connectors into the four-pin Molex power connection on the DVR and
into the side of the interface box (
The appropriate connections have been made between the DVR and the Test Kit. To view cameras that
have not been connected to the DVR, the input will have to be attached directly to the test kit:
8)
Use the 50-foot (15 m) expansion cable and plug the camera BNC into the BNC connector on the
test kit ( ).
9)
Press the REVERSE button located below the monitor to switch the camera's video from the DVR
chassis to the Test Kit.
Figure 34. Test Kit connections
1036564B / October 2002
ONNECTIONS
T
K
EST
IT TO THE
and
DVR
).

4 Testing Connections

and
). Power (24 VDC)