Command
Advanced Configuration
Test Patterns
Set pattern
View test pattern
HDCP Status
Query HDCP status of
an input
Query HDCP status of
all inputs
Video Signal Presence
View video signal
presence
Power Save
Power save off
Power save on
View power save status
KEY:
X!
Input number: 0 through 9999 (assigned by the VCS program). Response is four digits with leading zeros.
=
0 = Window without source.
1-999 = Physical video connections on all chassis in the system.
1000-9999 = VNC, image, text, and clock sources defined in the system
X#
Canvas number: 1 through 10. Response is two digits with leading zero.
=
0 = All canvases (for window mute and preset recall only).
X2@
=
Test pattern: 0 through 13. Response format is two digits, with a leading zero (see
definitions
on page 57 for a list of available test pattern).
X4$
Input HDCP status: 0 = No video detected, 1 = Video detected without HDCP,
=
2 = Video detected with HDCP v1.n.
X6!
Video signal status: 0 = Video signal not detected, 1 = Video signal detected.
=
X6@
Power save status: 0 = off (full power mode, default), 1 = power save on.
=
Quantum Ultra Videowall Processing System • Remote Configuration and Control
ASCII Command
Response
(Host to Processor)
(Processor to Host)
E X# * X2@ TEST }
Test X# * X2@ ]
E X# TEST }
X2@]
E I X! HDCP }
X4$ ]
In verbose modes 2 and 3:
Hdcp I
E I HDCP }
X4$ X4$
In verbose modes 2 and 3:
Hdcp I
E 0 LS }
X6! X6!
In verbose modes 2 and 3:
In00 •
E
}
0 PSAV
Psav 0
E
}
1 PSAV
Psav 1
E
}
X6@ ]
PSAV
In verbose modes 2 and 3:
Psav
Additional Description
Select test pattern
canvas
View the current test pattern
X2@
View HDCP status
input
X!
X4$ ]
*
X4$]
...
X4$
X4$
X4$
]
...
n
1
2
View HDCP status
inputs.
X6!]
...
X6!
X6!
X6!
]
...
n
1
2
View video signal presence
X6!
]
The Quantum Ultra runs in full
power mode (default).
]
The unit enters low power state
that can be exited only via the
Power Save Off command or a
power cycle.
View current power save status
X6@
.
X6@ ]
Test pattern symbol
X2@
for
X#
.
X#
on canvas
.
X4$
of
X!
.
X4$
of all
on all inputs.
67