Command
Information Requests
General information
Query model name
Query firmware version
Query firmware build
version
Query part number
View internal temperature
View SBC temperature
View I/O card
temperature
KEY:
X!
=
Input number: 0 through 9999 (assigned by the VCS program). Response is four digits with leading zeros.
0 = Window without source.
1-999 = Physical video connections on all chassis in the system.
1000-9999 = VNC, image, text, and clock sources defined in the system
X#
=
Canvas number: 1 through 10. Response is two digits with leading zero.
0 = All canvases (for window mute and preset recall only)
X$
Source format: 0 = No signal present, 1 = HDMI, 4 = H.264/MJPEG, 5 = VNC, 6 = Clock, 7 = Image file (.bmp,
=
.jpg, .tif, or .png)
X%
Window number: 1 through 999. Response is three digits with leading zeros.
=
0 = All windows (for window mute only)
X^
=
Quantum Ultra 610, Quantum Ultra 305, Quantum Ultra Connect 128, or Quantum Ultra Connect 84
=
X&
Quantum Ultra part number:
Quantum Ultra 610 = 60-1571-01
Quantum Ultra 305 = 60-1734-01
Quantum Ultra Connect 84 = 60-1898-01
Quantum Ultra Connect 128 = 60-1898-02
X1@
=
Internal temperature in degrees Celsius.
X1#
=
Vertical frequency: Response format is three digits with leading zeros and one decimal place.
X4@
=
Window mute: 0 = Off (unmute) (default), 1 = On (mute window)
X8)
=
Input resolution: Horizontal and vertical dimensions.
Quantum Ultra Videowall Processing System • Remote Configuration and Control
ASCII Command
Response
(Host to Processor)
(Processor to Host)
X#
X%
*
* I
Grp
(Responses are the same in verbose modes 2 and 3.)
1I
X^ ]
In verbose modes 2 and 3:
Inf01 *
Q
n.nn ]
In verbose modes 2 and 3:
Ver01 *
n.nn.nnnn-bnnn ]
*Q
In verbose modes 2 and 3:
Bld n
N
X& ]
In verbose modes 2 and 3:
Pno
E
}
X1@ ]
20STAT
In verbose modes 2 and 3:
20Stat •
E
}
X1@ ]
21STAT
In verbose modes 2 and 3:
21Stat •
E
}
X1@ ]
22STAT
In verbose modes 2 and 3:
212tat •
Additional Description
X#
X%
X!
X$
•Win
•In
•Typ
•Blk
View canvas (output group),
window, input selection,
source type, mute status,
input resolution, and vertical
frequency.
View Quantum Ultra model
name
X^ ]
View firmware version to the
second decimal place.
n.nn ]
View the full firmware version.
.nn.
-
]
nnnn
bnnn
View the Quantum Ultra part
number.
X& ]
View unit internal temperature
X1@
X1@ ]
View temperature
internal controller (SBC) in
degrees Celsius.
X1@ ]
View temperature
hottest input or output card.
X1@ ]
X4@
X8)
X1#]
•Res
•Vrt
X^
.
in degrees Celsius.
X1@
of the
X1@
of the
69
Need help?
Do you have a question about the Quantum Ultra Series and is the answer not in the manual?