Programming the Bell Outputs

1. Enter Data Field Program Mode [Installer Code] + [8 0 0].
2. Program the following data fields:
3. Enter Zone Programming in #93 Menu Mode (refer to the Quick Start Guide) to assign
4. Exit Program Mode by pressing 99.
The bell outputs will not respond if zones are not assigned to them. For fire alarms, the system
will display FIRE ALARM SILENCED. This message will also be displayed if the bell output is not
supervised.
www.PDF-Zoo.com
AB12 BELL/BOX WIRING
1
2
3
BELL

Figure 14-1: External Sounder Connections

08
Temporal Siren Pulse
13
Select Timeout for Bell 1
16
Confirmation of Arming Ding for Bell 1
1 47
Enable Chime for Bell 1
3 57
Confirmation of Arming Ding for Bell 2
3 59
Enable Chime for Bell 2
3 15
Select either Steady or Pulsing for each bell circuit output
3 60
Select Timeout for Bell 2
zones to bell outputs and/or auxiliary relay.
3
4
AB12 WIRING NOTES:
• Disconnect the AB12's factory-wired connection
from its terminal #4 to its outer box.
• Set field 3
*
function.
• Assign zone 6 to a burglary partition. Program
it for day trouble/night alarm response (type 05)
when this bell is used by only one burglary
partition. Program it for 24 hr. audible alarm
response (type 07) when this bell is used by
more than one burglary partition.
• All wiring from AB12 to panel must be run in
conduit.
2k EOLR
4
5
6
AB12 OUTER BOX
TAMPER
SWITCHES
INNER LINER
Section 14 – External Sounders