Sounder (Bell) Connections; Wiring The Ac Transformer; Figure 2-5 Using A Supplementary Power Supply For Keypads; Figure 2-6 Typical Sounder Wiring - ADEMCO VISTA-10ES Installation And Setup Manual

Table of Contents

Advertisement

VISTA-10SE Installation and Setup Guide

Sounder (Bell) Connections

1.
Make sounder connections to alarm output
terminals 3 (+) and 4 (–) on the control panel.
CONTROL
BOARD
_
4
ALARM
OUTPUT
+
3
Figure 2-6. Typical Sounder Wiring
For supervised output, continue with steps 2 and 3.
2.
Cut the red Bell Supervision Jumper located above
terminals 2 and 3 on the control board as indicated
in Figure 2-7.
3.
Connect a 1k ohm resistor across the terminals of
the last sounder, not across the control's terminals.
This control complies with NFPA requirements for
temporal pulse sounding of fire notification appliances.
Temporal pulse sounding for a fire alarm consists of:
3 pulses – pause – 3 pulses – pause – 3 pulses–etc.
• Use only UL Listed sounding devices for UL installations mounted indoors.
U L
• The total current drawn from the alarm output and the auxiliary power output, combined, cannot exceed
600mA. In addition, the sounding device must be a UL Listed audible signal appliance rated to operate
in a 10.2-13.8 VDC voltage range, and must be mounted indoors.

Wiring the AC Transformer

1321 Transformer
Wire the 1321 Transformer to terminals 1 and 2 on the
control board. Refer to wiring table at right for wire
gauge to use.
2-4
SUPPLEMENTARY
POWER SUPPLY
+
Figure 2-5. Using a Supplementary Power Supply for Keypads
NO. 702
SIREN
_
+
sounder_wir-V0
CONTROL TERMINAL STRIP
AUX. AUX. DATA
DATA
+
IN
4
5
6
IMPORTANT:
MAKE THESE
CONNECTIONS
DIRECTLY TO
SCREW
TERMINALS AS
SHOWN.
ALARM
OUTPUT
TERMINALS
CUT RED JUMPER ON
CONTROL BOARD
TO ENABLE BELL
(SOUNDER) SUPERVISION
Figure 2-7. Sounder Wiring (Supervised)
NOTES:
The 12VDC sounder output activates when an
alarm occurs.
Total current drawn from this output cannot exceed
2 amps (going beyond 2 amps will overload the
power supply, or may cause the electronic circuit
protecting the sounder output to trip).
You must install a battery, since the battery
supplies this current.
Distance of Transformer
From the Control Panel
Up to 50 feet
50 – 100 feet
100 – 250 feet
OUT
7
supp_pwr_supply-V0
TERMINALS ON
CONTROL BOARD
_
4
_
OBSERVE
POLARITY
+
+
3
IF BELL SUPERVISION IS ENABLED (RED JUMPER
ON CONTROL BOARD IS CUT), CONNECT A 1000
OHM RESISTOR ACROSS THE EXTERNAL
SOUNDER, AS SHOWN BY THE DASHED LINE.
DO NOT CONNECT THE RESISTOR AT THE
ALARM OUTPUT TERMINALS THEMSELVES!
WIRING TABLE
Wire Gauge
to Use
# 20
# 18
# 16
EXTERNAL
ALARM
SOUNDER
1000
OHM
EOL
RESISTOR
bell_suprv_wir-V0