3. Frame Installation
※ Precautions when tightening screws
Standard installation requirements by wall type
Check the wall type before installation.
Frames can be installed on a sufficiently thick concrete or interior wall.
Refer to the following figures.
At least 50 mm
Equipped with
stiffeners, e.g. MDF
or PW (plywood)
At least 50
mm
At least 10 mm
MDF, PW (plywood)
At least 25
mm
MDF, PW (plywood)
(except the plaster
Art Wall
board thickness)
At least 25
mm
Concrete composite wall
(except the plaster board
thickness)
•
First check the wall specifications (e.g.
type, thickness, floor plan).
At least 30 mm
Wall
MDF, PW (plywood)
At least 10 mm
MDF, PW (plywood)
If installing frames on a wall that is
not flat, irregular openings may
develop and affect the exterior
appearance.
At least 30 mm
Concrete
At least 10 mm
MDF, PW (plywood)
①
Sufficiently thick concrete or design wall
②
Wood stud inside a plaster board, or MDF wall
Installation requirements
•
Make sure you check the location of the wood stud inside the
wall before screwing screws into the wall.
•
Minimum wood stud size: 51 x 102 mm (2 x 4 inches)
Drill holes (3 mm) before screwing screws into the wall.
•
Make sure you drill screw holes in the middle of the wood stud.
•
If you screw a screw directly into the wood stud without drilling
a hole, the wood may crack.
•
Standard wood stud interval of 16" is supported. (24" is not
supported.)
Samsung Electronics is not responsible for problems
caused as a result of failure to follow the requirements
specified in the installation guide.