9.

AV Handle System

The handle housing and crankcase
are connected by vibration damping
rubber buffers. Damaged rubber
buffers (annular buffers) must
always be replaced.
– Remove the air filter, b 12.2.1
– Remove the shroud, b 6.4
3
: Take out the screw (1).
: Remove the sleeve (2).
: Take out the screws (3).
: Remove the annular buffer (4).
Remove the tank housing for
access to the other rubber buffers,
b 12.8
60
: Pry the annular buffers (arrows)
out of the crankcase.
4
1
2
: Push the stop buffer out of its
seat and take it away.
1
: Push the stop buffer into the
guide so that the groove (1)
engages the housing rib (2).
2
1
: At the clutch side, push the
annular buffer home from the
outside so that its groove (1)
engages the housing rib (2).
: At the starter side, push the
annular buffer home from outside
so that its groove (1) engages the
housing rib (2).
Install all other parts in the reverse
sequence.
2
2
1
MS 460, MS 460 C

Advertisement

Table of Contents
loading

Table of Contents