7.3.2
Installing
Degrease crankshaft stub and bore
in flywheel hub with standard
solvent-based degreasant
containing no chlorinated or
halogenated hydrocarbons,
b 16.
: Check that key (arrow) is properly
seated.
– Fit the flywheel in position.
– Fit and tighten down the flywheel
nut firmly, b 3.5
Assemble all other parts in the
reverse sequence.
50
7.4

Stop Switch

2 1
– Remove the switch shaft,
b 10.1
– Rotate the switch housing until
the switch actuator is exposed.
: Pull out the switch actuator (1)
and spring (2).
: Carefully push the switch
housing sideways and lift it away.
– When installing, push home the
switch actuator until it snaps into
position.
7.5

Wiring Harness

1
2
– Remove the ignition module,
b 7.1
: On machines with heated
handles, pull pin connector (1)
out of the socket (2).
: Pull the grommet (arrow) out of
the tank housing and off the
wires.
: Pull the wires sideways out of the
tank housing.
– Remove the carburetor, b
12.2.1
MS 460, MS 460 C