8. AV HANDLE SYSTEM

The handle and engine housings are
connected by vibration-damping,
ring-shaped rubber buffers.
Damaged rubber buffers must
always be replaced.
Upper rubber buffers, clutch side:
Note: See chapter 9.5 for
information on replacement.
Lower rubber buffers, clutch side:
• Prise stoppers out of rubber
buffers.
• Unscrew screws from rubber
buffers.
• Prise rubber buffers out of cast
arm.
• Press rubber buffers into cast
arm until outer groove (1)
engages chamfer (2).
- Tighten screws with a torque
of 6.0 Nm.
Rubber buffers, ignition side:
- Remove fan cover, see 6.3.2.
• Prise stoppers out of rubber
buffers.
• Unscrew screws from rubber
buffers.
• Prise rubber buffers out of
crankcase.
• Press rubber buffers in from the
outside until outer groove (1)
engages housing chamfer (2).
- Tighten screws with a torque of
6.0 Nm.