FUNCTIONAL
Power Supply
Dead Zone
Measurable Distance
Transmitting frequency
Update Time
Beam angle
PERFORMANCE
Accuracy
Ambient Temperature
Ambient Pressure
Process Temperature
Output signal
HART Communication
Load
Maximum Line Length
Humidity
Dielectric Constant
PHYSICAL
Material
Protection
Conduit Entry
Mass
Mounting
ENVIRONMENTAL
Location
Altitude
Installation Category
Pollution Degree
*Under severe EMI/EMC environments per IEC61326-1 or NAMUR NE21, the device error may increase to a maximum of 1"
(25 mm)
APPROVALS & RATINGS
FM and CSA
Hazardous: Dust Ignition Proof: Class II, Div1, Groups E, F, G; Class III T4
Hazardous: Non-incendive: Class I, Div 2, Groups A, B, C, D, T4
CE
Electromagnetic Compatibility Directive
Low Voltage Directive
MPR180416 Rev. B
Nominal 24 VDC with max 550 Ohm loop resistence; Maximum 30 VDC
15.7 in. (400 mm) from mounting plate
131 ft (40 m) or 328 ft (100 m)
78 to 79 GHz FMCW
Maximum 10 seconds (depending on Settings)
4 degrees
0.2 in. (5mm)* including hysteresis and non-repeatability
-40 to 175 °F (-40 to 80 °C)
12 to 15 psi ( 860 to 1060 mbar)
-40 to 392 °F (-40 to 200 °C)
4 to 20 mA
230 to 550 Ohm; 230 to 500 Ohm when connecting a coupling module
4921 ft (1500 m) multi-wire
45 to 75% relative humidity
Minimum dK of 1.6 for ranges up to 65.6 ft (20 m)
Minimum dk of 2.5 for ranges up to 328 ft (100 m)
316 Stainless Steel with polyurethane powder coat finish
Type 4X/NEMA 4X; Type 6/NEMA 6, IP68
1/2" NPT
6.94 lb (3.15 kg) (with 3" SS flange)
4, 6 or 8 in. flange or aiming flange
Indoor/outdoor
16,404 ft (5000 m) max
I
4
5
www.bindicator.com