Provide an environment suitable to the housing rating and materials of construction
Ambient Temperature: -40 to 176 °F (-40 to 80 °C)
Process Temperature: -40 to 392 °F (-40 to 200 °C)
AIMER ADJUSTMENT
Aiming will assist in measuring material in the cone, but is generally not required for signal optimation.
Once location of the unit has been determined, use flange to mount; if using an aimer flange, see instructions below.
1.
For 4" and 6" Aimer: Loosen the set screws in the locking ring. Holding the
electronics enclosure firmly, loosen the Aimer locking ring using the supplied
C spanner, until the unit drops down slightly. The enclosure can then be turned
freely.
2.
Direct the MP SERIES air radar so the antenna is pointed at an angle perpendicular
to the material surface, if possible.
3.
When the desired position is reached, re-tighten the locking ring using the
Cspanner, and tighten set screws.
Note: Aiming will assist in measuring material in the cone.