REQUESTING AN ECHO PROFILE
1.
In Program mode, navigate to Level Meter > Diagnostics (3) > Echo Profile (3.2)
2.
Press RIGHT arrow to request a profile.
3.
Use UP and DOWN arrows to scroll to an icon on the right of the screen. When an icon is highlighted, that feature
becomes active.
4.
To move a cross-hair, press RIGHT arrow to increase the value, LEFT arrow to decrease.
5.
To Zoom into an area, position the intersection of the cross-hairs at the center of that area, select Zoom, and press
RIGHT arrow . Press LEFT arrow to Zoom out.
6.
To update the profile, select Measure and press RIGHT arrow.
7.
To return to the previous menu, select Exit then press RIGHT arrow.
Con dence
TVT
DEVICE ADDRESS
In PROGRAM mode, navigate to: Level Meter > Communication (5) > Device Address (5.2) to view the device address.
Press MODE to return to Measurement mode.
Distance from Low Calibration
Point to vertical cross hair
Algorithm
Distance from ange face to target
Pan left/right - selected
Echo
Pan up/down
Zoom
Measure
Exit