Bindicator F78MP Series Installation & Operation Manual page 7

Air radar
Table of Contents

Advertisement

FCC CONFORMITY
US Installations only: Federal Communications Commission (FCC) rules
WARNING: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY BINDICATOR COULD VOID THE
USER'S AUTHORITY TO OPERATE THE EQUIPMENT.
This device has been tested and found to comply with the limits Class B digital device part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment.
This device has also been tested and found to comply with the limits §15.256, Subpart C-Intentional radiators,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This device generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications, in which case the user will be
required to correct the interference at his/her own expense.
This device is certified to measure levels in fixed or mobile enclosed tanks.
This device may be used to measure levels in open air environments or outside enclosed tanks, subject to the
following conditions:
Devices shall be installed and maintained to ensure a vertically downward orientation of the transmit antenna's
main beam.
Devices shall be installed only at fixed locations. Devices shall not operate while being moved or while inside a
moving container.
Hand-held applications and residential use are prohibited.
R&TTE COMPLIANCE (EUROPE)
Hereby, Bindicator, declares that the MP Series Air Radar is in compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC.
The MP Series Air Radar complies with EN 302 372 for use in closed storage vessels, when installed according to the
installation requirements of EN 302 372, and may be used in all EU countries.
The MP Series Air Radar complies with EN 302 729 for use outside of closed tanks in EU countries. For open air
installations, the following conditions must be observed:
Installation and maintenance is performed by suitably qualified and trained personnel.
The MP Series Radar shall be installed only in a permanent fixed position pointing downwards. Its location shall
comply with the following two restrictions:
1.
It shall be installed with a minimum separation distance of 2.5 miles (4 km) from Radio Astronomy sites listed at
www.craf.eu/raobs.htm unless special authorization has been provided by the responsible national regulatory
authority.
2.
If it is installed at a location between 2.5 and 25 miles (4 and 40 km) from any Radio Astronomy site listed at
www.craf.eu/raobs.htm, the MP Series Air Radar shall be installed at a height not exceeding 50 ft (15m) from the
ground.