LEVEL APPLICATION EXAMPLE
The application is a vessel that takes an average 3 hours (180 minutes) to fill and 3 weeks to empty.
Fill rate = 0.08 m/minute [(Low Cal Pt. minus High Cal Pt)/fastest of fill or empty time]
= (15.5 m - 1 m) / 180 min.
= 14.5 m / 180 min.
= 0.08 m/min
Therefore SLOW response rate (0.1 m/min) can be selected.
Quick Start Parameter
Vessel
Response Rate
Units
Operation
Low Calibration Point
High Calibration Point
Sensor Reference Point
Low Calibration Point
MPR180416 Rev. B
Setting
Description
STEEL
Selects vessel construction material.
SLOW
Resets Fill Rate/ Empty Rate to 0.1 m/minute.
M
Sensor measurement units.
LEVEL (1)
Material level referenced from Low Cal. Point.
15.5
Process empty level.
1.0
Process full level.
15.5 m
1.0 m
High Calibration
Point
Level
17