Installing and connecting SDI and ethernet ports
Table 26
Default port configuration for the NDK20EA SSC card
Port
0
MTC/SCH/BUG
1
MTC/SCH/BUG
2
MTC/SCHBUG
553-3021-210
Standard 7.00
Use
Baud rate
Set by a DIP switch
1200 (See Note 1)
1200 (See Note 2)
Procedure 34 on page 216 describes how to connect a terminal, modems and
other devices such as CDR devices and additional TTYs to the SSC card.
Procedure 34
Connecting SDI ports on the SSC card
1
Connect the NTBK48 3-port SDI cable to the 9-pin SDI connection
at the top of the main or IP expansion cabinet.
Figure 89
Cable connection
NTBK48 cable connection
January 2002
Data bits
8
8
8
NTBK48 cable connection
Stop bits
Parity
1
None
1
None
1
None