Installing the circuit cards

NT1R20 Off-Premise Station (OPS) analog line card

553-3021-210
Standard 7.00
The OPS analog line card provides eight OPS lines. The card can be installed
in slots 1 through 10 in the main cabinet or 11 through 50 in the expansion
cabinets.
Procedure 30
OPS Analog card installation
1
Set the jumpers on the NT1R20 OPS card.
Each line interface unit, on the card, is equipped with two jumper
blocks that are used to select the proper loop current, depending upon
loop length (Refer to Table on page 194 and Figure 80 on page 196).
For units connected to loops of 460 to 2300 ¾, both jumper blocks for
that unit must have jumper straps installed. For loops that are 460 ¾
or less, jumper straps are not installed.
Figure 79
Set the jumpers
2
Insert the OPS card in its assigned slot.
The card may be installed in card slots 1 through 50.
3
Cross connect off-premise telephones as described in
"Connecting the trunks" on page 277.
Refer to Figure 81 on page 197 for cross connection information for the
OPS card.