Ntak03 Tds/Dtr Card - Nortel Meridian 1 Option 11C Planning And Installation Manual

Hide thumbs Also See for Meridian 1 Option 11C:
Table of Contents

Advertisement

Page 190 of 408
Installing the circuit cards
Table 21
Jumper settings
Jumper
Port
location
Port 0
J10
Port 1
J7
J6
Port 2
J5
Port 3
J4
J3

NTAK03 TDS/DTR card

553-3021-210
Standard 7.00
Strap for
DTE
C - B
C - B
C - B
C - B
C - B
C - B
2
Insert the card in its assigned slot.
The NTAK02 SDI/DCH card may be installed in card slots 1
through 10.
3
Connect an NTAK19FB four port cable (or an NE-A25-B cable)
from the corresponding connector at the bottom of the cabinet. If
using an NE-A25-B cable, terminate it at the cross-connect terminal
(since the NTAK19FB cable is equipped with connectors, it does not
require termination at the cross-connect terminal).
The function of the NTAK03 TDS/DTR card is provided on the NDK20EA
SSC card. However, the TDS/DTR card can coexist with the SSC card if you
wish to access extra TDS/DTR units or SDI ports. These functions must be
manually programmed in the software overlays.
Note: The system may not operate properly if an NTAK03 circuit card
is installed in a slot connected to telephones. Refer to"Installing and
connecting SDI and ethernet ports" on page 213, to connect an NTAK03
circuit card to the cross-connect terminal.
January 2002
Strap for
Jumper
DCE
location
B - A
B - A
J9
B - A
J8
B - A
B - A
J2
B - A
J1
RS422
RS232
C - B
B - A
C - B
B - A
C - B
B - A
C - B
B - A