Monitor System Components
4
Temperature Status
4-14
Connectrix B Series XPath OS AP-7420B Hardware Reference Manual
The possible status values are:
OK – Power supply present and functioning correctly.
NOT PRESENT – Power supply not present.
FAIL – Power supply present but faulty.
Use the
tempshow
temperature sensor in the AP-7420B (the number can vary on
different platforms).
To display the temperature status:
1. Log in to the AP-7420B as admin.
2. Enter the
Example
APswitch:admin> tempshow
Index
----------------------------------------------------
1
2
3
4
5
APswitch:admin>
The possible temperature status values are:
OK – Temperature is within acceptable range.
FAIL – Temperature is outside of acceptable operating range
o
(10
C /50
command to display information for each
command:
tempshow
Status
Centigrade
OK
21
OK
22
OK
29
OK
24
OK
25
o
o
/
o
F to 40
C
104
F ). Damage might occur.
Fahrenheit
70
72
84
75
77

Advertisement