3 ELECTRICAL INSTALLATION / EARTHING
3.11 Regulations: The electrical installation must be carried out in
3.12 Safety: In the interests of electrical safety a 30 mA residual current
3.13 Before starting work on the electrical installation ensure the power
3.14 The motor and wiring must not be exposed to water.
3.15 The supply cable must be positioned so that it is not stepped on,
3.16 Electrical Connection:
a) The pump is provided with a factory fitted supply cord.
b) This must be permanently connected to the fixed wiring of the mains
supply.
c) Means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring regulations.
d) A suitable method of connection would be via a dedicated double pole
switched, fused connection unit complying with BS 1363-4, protected with
a fuse (see technical specification section).
e) The connection unit should be mounted in an easily accessible position
and should be labelled if confusion is possible, to allow easy identification
of the flomate isolating switch.
3.17 Earthing: This appliance must be earthed via the supply cord, which must be
correctly connected to the earth point located in the terminal box.
3.18 Additional earthing: Certain installations may require additional earthing
arrangements such as equipotential bonding. Reference should be made to
the relevant regulations concerning this subject to ensure compliance.
3.19 Wiring Of Connection Unit:
The wires in the mains lead (supply cord) are coloured in accordance with the
following code:
Green and Yellow: Earth
Blue: Neutral
Brown: Live
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in your
connection unit proceed as follows:
The wire which is coloured green and yellow must be connected to the
z
terminal in the connection unit which is marked with the letter E or by the
earth symbol:
The wire which is coloured blue must be connected to the terminal which
z
is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal
z
which is marked with the letter L or coloured red.
accordance with the current national electrical regulations and
installed by a qualified person.
device (R.C.D. not supplied) must be installed in the supply circuit.
This may be part of a consumer unit or a separate unit.
supply is isolated.
cut or damaged.
WARNING: This appliance must be earthed.
or coloured green or green and yellow.