4 PRIMING

4.11 Priming: This pump is self venting. Open the mains stopcock and allow the
pump to fill and vent, please note the pump chamber must be full of liquid at
all times. Seal damage will result if the pump runs dry. Do not run the pump
dry.
4.12 Starting:
a) Ensure all outlets are closed, turn power supply 'on'.
b) Open and close all outlets in turn associated with the pump allowing liquid
to flow from each outlet until all air is purged. As each outlet is opened
and closed the pump will start and stop respectively.
c) Any tap or control valve within the system when opened and closed will
now turn the pump on/off. Check system for leaks, if clear the system is
now operating correctly
d) Carefully check pump and pipework for leaks whilst pump running and
stationary before leaving the installation unattended.
4.13 For Further Technical Support: Phone the Stuart Turner TechAssist team
on +44 (0) 800 31 969 80. Our staff are trained to help and advise you over
the phone.
Note: When pumps are installed in another manufacturers original equipment,
please contact the manufacturer for advice.

5 MAINTENANCE

5.11 Disconnect electrical supply before working on pump.
5.12 Turn off liquid supplies to the pump and release pressure by opening outlets
before attempting maintenance.