2 LOCATION - GENERAL
2.11
2.12 Protection: The pump must be located in a dry position, frost free
2.13 Ventilation: Ensure an adequate air flow to cool the pump.
2.14 Safety: The motor casing can become very hot under normal
2.15 Water retention: Site the pump in a location where in the unlikely
2.16 Location point: The pump must be located after the mains water stop cock,
in-line to the connection to the boiler. Do not site the pump in the roof
space, since air locks can easily result.
2.17 Pump position: The pump must be positioned on its anti-vibration mounting
feet and as close to the water source as possible.
2.18 Direction of flow: Ensure the water flow is in the direction of the arrow, as
marked on the flow switch reed clamp.
Access: For emergencies and maintenance the pump must be
easily accessible.
and protected from freezing. Ensure the pump is in a dry position,
away from heat sources, such as radiators and heaters.
Separate the pump from other appliances that generate heat. An
80 mm air gap must be maintained to allow free air flow through
the fan cowl and over the motor at all times.
operating conditions. Care must be taken to ensure it cannot be
touched during operation.
event of a water leak, any spillage is contained or routed to avoid
electrics or areas sensitive to water damage.
- 7 -